? phoenix contact - 11/2009 101174_en_01 interface emg ...-dio .../lp data sheet 1description lamp test circuits, which decouple signals in isolation, should be implemented us ing two module versions: ? the diodes are connected in pairs and can be freely wired to the anode ? the anode of each diode pair is connected to a common connection point figure 1 lamp test circuit (emg 45-dio14m/lp) 2 1 4 3 6 5 8 7 10 9 12 11 14 13 m m l/? l/+ l/+ note: please note that there is no isolation between the individual diode paths within a module. make sure you always use the latest documentation. it can be downloaded at www.phoenixcontact.net/download . this data sheet is valid for all pr oducts listed on the following page: lamp testing modules
emg ...-dio .../lp 101174_en_01 phoenix contact 2 2ordering data 3 technical data lamp testing modules description housing width type order no. pcs./pkt. lamp testing modules , 2 diodes each with common cathode: 4-pair version, for individual wiring 45 mm emg 45-dio 8e/lp 2954798 5 7-pair version, with common co ntrol 45 mm emg 45-dio14m/lp 2950132 5 8-pair version, for individual wiring 90 mm emg 90-dio 16e/lp 2954808 5 16-pair version, with common control 90 mm emg 90-dio 32m/lp 2954785 5 accessories description type order no. pcs./pkt. device marking label emg-gks 12 2947035 50 general data ambient temperature range -20c ? +50c rated insulation voltage according to en 50178 300 v pollution degree according to en 50178 2 surge voltage category according to en 50178 3, basic insulation mounting position any installation can be aligned without spacing height 55 mm length 75 mm connection data conductor cross-section, solid 0.2 mm2 ... 4 mm2 conductor cross-section, stranded 0.2 mm2 ... 2.5 mm2 conductor cross-section, awg 24 - 12 stripping length 8 mm connection method screw connection diode data emg 45-dio 8e/lp, emg 90-dio 16e/lp emg 45-dio14m/lp, emg 90-dio 32m/lp maximum operating voltage u max 250 v ac 250 v ac peak reverse voltage per diode 1300 v 1300 v reverse current per diode 5 a 5 a conducting-state voltage per diode 0.8 v, approximately 0.8 v, approximately conducting-state current per diode with single load with simultaneous load 0.7 a 0.4 a 0.7 a 0.2 a conformance/approvals conformance ce-compliant conformance with low voltag e directive (lvd) 2006/95/ec electronic equipment according to en 50178
emg ...-dio .../lp 101174_en_01 3 phoenix contact gmbh & co. kg ? 32823 blombe rg ? germany ? phone: +49 - 52 35 - 30 0 phoenix contact ? p.o.box 4100 ? harrisburg ? pa 17111-0100 ? usa ? phone: +717-944-1300 www.phoenixcontact.com 4circuit diagram 4.1 lamp testing module, ca n be wired individually figure 2 emg 45-dio 8e/lp figure 3 emg 90-dio 16e/lp 4.2 lamp testing module, negative polarity figure 4 emg 45-dio14m/lp figure 5 emg 90-dio 32m/lp 2 1 3 5 4 68 7 911 10 12 2 1 35 4 68 7 911 10 12 13 16 19 22 14 15 17 18 20 21 23 24 2 1 4 3 6 5 8 7 10 9 12 11 14 13 m m 2 1 4 3 6 5 8 7 10 9 12 11 14 1 3 16 1 5 1 7 1 9 21 2 3 2 5 2 7 2 93 1 m 18 20 22 24 26 28 30 32 m
|